Setting up Automgen¶
Requirements
- Automgen Edition or Ultimate Edition
- Automgen
Sample Project
Follow the next steps to configure AUTOMGEN to work with Factory I/O:
-
Double click on Configuration > Post-processors > PC > I/O Drivers.
-
Select the tcp-ip client driver from Driver(s) available and click on Add.
-
Click on the previously added tcp-ip client driver and click on Set parameters.
-
Insert the Server name or the IP address of the computer where Factory I/O is running. If they are running on the same computer you may use localhost as the server name.
-
Insert 16 as the Number of digital inputs to read from server and the Number of digital outputs to write to server.
-
Insert 8 as the Number of input words to read from server and the Number of output words to write to server.
-
Insert 200 as the First input word number on both Client side and Server side.
-
Insert 300 as the First output word number for both Client side and Server side.
Note that the number of Digital and WORD inputs/outputs defined in AUTOMGEN must match the ones defined in Factory I/O. These values vary from scene to scene.
-
Double click on Configuration > Post-processors > PC > Run and change the Value in milliseconds to 8.