Skip to content

Operators

operators

Emergency Stop

Two-position red trigger action and non-illuminated push button (mushroom head). Usually used in emergency events.

  • Normally closed contact type

emergency stop

Tag Controller I/O Type Description
Emergency Stop # Input Bool Emergency stop activated.

Push Buttons

Illuminated push buttons available in different colors compliant with the IEC 60204-1:2016 standard. Can be used as a momentary or alternate action, according to the selected configuration. The push button color can be changed on the context menu.

  • Start, Reset, and Stop (normally closed) push buttons
  • Two generic push buttons: Push Button NO (normally open) and Push Button NC (normally closed)
  • Colors compliant with IEC 60204-1:2016 standard
Actuator Colors Notes
Start/On White, Grey, Black or Green
Reset Blue, White, Grey or Black
Stop/Off Black, Grey or White Red is permitted when not used near and emergency button
Abnormal conditions Yellow e.g. interruption of an automatic cycle

push buttons

Configurations

Momentary Action

Tag Controller I/O Type Description
Push Button # Input Bool Pressed.
Push Button # (Light) Output Bool Light on/off.

Alternate Action

Tag Controller I/O Type Description
Push Button # Input Bool Toggle on/off.
Push Button # (Light) Output Bool Light on/off.

Light Indicators

Panel mount light indicator. Commonly used on instrument panels for safety applications or status indication.

  • Available in different colors compliant with the IEC 60204-1:2016 standard.

light indicators

Tag Controller I/O Type Description
Light Indicator # Output Bool Light on/off.

Selector

Non-illuminated selector switch mainly used to define the current state of a variable or task. Left-click and drag to toggle between states. State 0 is selected by default.

selector

Configurations

2 Position

Tag Controller I/O Type Description
Selector # (State 0) Input Bool State 0 selected.
Selector # (State 1) Input Bool State 1 selected.

3 Position (A)

Tag Controller I/O Type Description
Selector # (State 1) Input Bool State 1 selected.
Selector # (State 2) Input Bool State 2 selected.

3 Position (B)

Tag Controller I/O Type Description
Selector # (State 1) Input Bool State 1 selected.
Selector # (State 2) Input Bool State 2 selected.

Potentiometer

Used to generate an analog value proportional to the knob rotation. The selected configuration can define the value range.

potentiometer

Configurations

[0, 10] V

Tag Controller I/O Type Description
Potentiometer # (V) Input Float Current value.

[-10, 10] V

Tag Controller I/O Type Description
Potentiometer # (V) Input Float Current value.

[-5, 5] V

Tag Controller I/O Type Description
Potentiometer # (V) Input Float Current value.

Digital Display

Allows numerical values to be displayed during the simulation. The selected configuration defines the value range and data type.

digital display

Configurations

[0, 10] V

Tag Controller I/O Type Description
Digital Display # Output Float Displays value.

[-10, 10] V

Tag Controller I/O Type Description
Digital Display # Output Float Displays value.

Integer

Tag Controller I/O Type Description
Digital Display # Output Integer Displays value.

BCD

Tag Controller I/O Type Description
Digital Display # Output Unsigned packed BCD Displays value.

Hexadecimal

Tag Controller I/O Type Description
Digital Display # Output Hexadecimal Displays value.

Electric Switchboard

Used to design an electric board with operators.

electric switchboard

Column

Metal structure typically used to hold an electric switchboard.

column