Operators
Emergency Stop
Two-position red trigger action and non-illuminated push button (mushroom head).
Usually used in emergency events.
- Normally closed contact type
Tag |
Controller I/O |
Type |
Description |
Emergency Stop # |
Input |
Bool |
Emergency stop activated. |
Illuminated push buttons available in different colors compliant with the IEC 60204-1:2016 standard.
Can be used as a momentary or alternate action, according to the selected configuration.
The push button color can be changed on the context menu.
- Start, Reset, and Stop (normally closed) push buttons
- Two generic push buttons: Push Button NO (normally open) and Push Button NC (normally closed)
- Colors compliant with IEC 60204-1:2016 standard
Recommended colors by order of preference according to IEC 60204-1:2016
Actuator |
Colors |
Notes |
Start/On |
White, Grey, Black or Green |
|
Reset |
Blue, White, Grey or Black |
|
Stop/Off |
Black, Grey or White |
Red is permitted when not used near and emergency button |
Abnormal conditions |
Yellow |
e.g. interruption of an automatic cycle |
Configurations
Momentary Action
Tag |
Controller I/O |
Type |
Description |
Push Button # |
Input |
Bool |
Pressed. |
Push Button # (Light) |
Output |
Bool |
Light on/off. |
Alternate Action
Tag |
Controller I/O |
Type |
Description |
Push Button # |
Input |
Bool |
Toggle on/off. |
Push Button # (Light) |
Output |
Bool |
Light on/off. |
Light Indicators
Panel mount light indicator. Commonly used on instrument panels for safety applications or status indication.
- Available in different colors compliant with the IEC 60204-1:2016 standard.
Tag |
Controller I/O |
Type |
Description |
Light Indicator # |
Output |
Bool |
Light on/off. |
Selector
Non-illuminated selector switch mainly used to define the current state of a variable or task.
Left-click and drag to toggle between states. State 0 is selected by default.
Configurations
2 Position
Tag |
Controller I/O |
Type |
Description |
Selector # (State 0) |
Input |
Bool |
State 0 selected. |
Selector # (State 1) |
Input |
Bool |
State 1 selected. |
3 Position (A)
Tag |
Controller I/O |
Type |
Description |
Selector # (State 1) |
Input |
Bool |
State 1 selected. |
Selector # (State 2) |
Input |
Bool |
State 2 selected. |
3 Position (B)
Tag |
Controller I/O |
Type |
Description |
Selector # (State 1) |
Input |
Bool |
State 1 selected. |
Selector # (State 2) |
Input |
Bool |
State 2 selected. |
Potentiometer
Used to generate an analog value proportional to the knob rotation.
The selected configuration can define the value range.
Configurations
[0, 10] V
Tag |
Controller I/O |
Type |
Description |
Potentiometer # (V) |
Input |
Float |
Current value. |
[-10, 10] V
Tag |
Controller I/O |
Type |
Description |
Potentiometer # (V) |
Input |
Float |
Current value. |
[-5, 5] V
Tag |
Controller I/O |
Type |
Description |
Potentiometer # (V) |
Input |
Float |
Current value. |
Digital Display
Allows numerical values to be displayed during the simulation.
The selected configuration defines the value range and data type.
Configurations
[0, 10] V
Tag |
Controller I/O |
Type |
Description |
Digital Display # |
Output |
Float |
Displays value. |
[-10, 10] V
Tag |
Controller I/O |
Type |
Description |
Digital Display # |
Output |
Float |
Displays value. |
Integer
Tag |
Controller I/O |
Type |
Description |
Digital Display # |
Output |
Integer |
Displays value. |
BCD
Tag |
Controller I/O |
Type |
Description |
Digital Display # |
Output |
Unsigned packed BCD |
Displays value. |
Hexadecimal
Tag |
Controller I/O |
Type |
Description |
Digital Display # |
Output |
Hexadecimal |
Displays value. |
Electric Switchboard
Used to design an electric board with operators.
Column
Metal structure typically used to hold an electric switchboard.